Terminal Technology in ENYCASE DK Junction Boxes

The Junction Box is an integral part of distribution & protection circuits in Power Electrical System. The Junction Box provides circuit integrity in the system; be it for Lighting Application Boxes or an Emergency Circuit or between sophisticated equipments like a Reactor and its Control Room.

An Electrical Power Junction Box contains a connection of cables & wires of same or different cross section area and also different types i.e. solid or stranded. The terminals therefore become one of important components in Electrical Power Distribution.

These connecting terminals are used in different voltage & current carrying conditions. The dielectric breakdown of the insulation of terminal is also influenced by relative humidity, temperature and degree of pollution in the environment.

Considering Clearance & Creepage distances – It is not only to address the spacing issues

Electricity likes to travel along the path of least resistance, looking for the best path for electricity usually means measuring the distance from one conductor to another conductor. The shortest distance may be through air (Air Gap) or along the surface of the insulation (Creepage Distance).

Creepage Distance - Creepage is the shortest path between two conductive parts (or between a conductive part and the bounding surface of the equipment) measured along the surface of the insulation.  A proper and adequate Creepage distance protects against tracking of insulation. Tracking is a process that produces a partially conducting path of localized deterioration on the surface of an insulating material as a result of the electric discharges on or close to an insulation surface. Tracking that damage the insulating material normally occurs because of one or more of the following reasons:

1.    Humidity in the atmosphere.

2.    Presence of contamination.

3.    Corrosive chemicals.

4.    Altitude at which equipment is to be operated.

Clearance Distance - Clearance is the shortest distance between two conductive parts (or between a conductive part and the bounding surface of the equipment) measured through air. Clearance distance helps prevent dielectric breakdown between electrodes caused by the ionization of air. The dielectric breakdown level is further influenced by relative humidity, temperature, and degree of pollution in the environment.



Considering Clearance & Creepage distances can avoid a problem later.

HENSEL offers a reliable & safe technology of terminals for Electrical Power Branching & Distribution through Junction Boxes. The terminals are designed for Clearance & Creepage distance with protective shrouds and are vibration proof. Each terminal pole are designed & defined to hold conductors of various cross sections and also different kinds of conductors (solid or stranded).

Thanks to HENSEL design which also has clear marking on the terminals viz. Rated Voltage, Rated Cross Section Capacity, etc.

HENSEL has wide range of terminals available for Power Connections.

The range – 1.5 sq. mm up to 240 sq. mm